(ONE LIGHTING COIL MODEL)

(1) Battery
(2) Fuse (10A)
(3) Rectifier
(4) Lighting coil
R : Red
G : Green
B : Black
(TWO LIGHTING COILS MODEL)

(1) Battery
(2) Fuse (10A)
(3) Rectifier
(4) Lighting coil
R : Red
G : Green
G/W : Green/White
B : Black
CHECKING THE BATTERY
Check:
- Battery electrolyte level and specific gravity
Refer to "CHECKING THE BATTERY" on page 3-17.
CHECKING THE LIGHTING COIL

Measure:
- Lighting coil output peak voltage Below specification -» Replace the lighting coil.
| Lighting coil output peak voltage (One lightning coil model): Green (G) - Green (G) |
||||
|---|---|---|---|---|
| r/min | Cranking | Cranking | 1,500 | 3,500 |
| r/min | Opened | Closed | Opened | Opened |
| D.C.V | 3.5 | 3.5 | 14 | 33 |
| Lighting coil output peak voltage (One lightning coil model): Green (G) - Green (G) |
|
|---|---|
| Reference value | 0.24 - 0.36 Ω |
| Lighting coil output peak voltage (Two lightning coil model): Green (G) - Green (G) |
||||
|---|---|---|---|---|
| r/min | Cranking | Cranking | 1,500 | 3,500 |
| r/min | Opened | Closed | Opened | Opened |
| D.C.V | 8.4 | 8.4 | 33.6 | 77.0 |
| Lighting coil output peak voltage (Two lightning coil model): Green (G) - Green (G) |
|
|---|---|
| Reference value | 0.61 - 0.91 Ω |
Peak voltage adaptor: YU-39991/90890-03172
CHECKING THE RECTIFIER AND RECTIFIER/REGULATOR

Measure:
- Rectifier output peak voltage
- Rectifier/regulator output peak voltage
Below specification -> Replace the rectifier or rectifier/regulator.
| Rectifier output peak voltage [B] Red (R) - Black (B) |
||||
|---|---|---|---|---|
| r/min | Cranking | Cranking | 1,500 | 3,500 |
| r/min | Opened | Closed | Opened | Opened |
| D.C.V | 2.8 | - | 13.3 | 32.2 |
When measuring closed (cranking),1500 r/min, and 3500 r/min, disconnect the positive (+) terminal of the battery

| Rectifier output peak voltage [B] Red (R) - Black (B) |
||||
|---|---|---|---|---|
| r/min | Cranking | Cranking | 1,500 | 3,500 |
| r/min | Opened | Closed | Opened | Opened |
| D.C.V | 7.7 | - | 27 | 27 |
When measuring closed (cranking), 1500 r/min, and 3500 r/min, disconnect the positive (+) terminal of the battery.
Peak voltage adaptor: YU-39991/90890-03172
Before measuring the rectifier or the rectifier/regulator peak voltage, make sure that no abnormality is observed on the lighting coil.