Owner's Manual DF250, DF225 Water In Fuel Alert System

Owner's Manual DF250, DF225 Water In Fuel Alert System
Suzuki Marine

CANCELLATION

  1. Turn the ignition key to the “ON” position.

  2. Pull out the emergency stop switch plate (1).

  3. Pull up the emergency stop switch knob (2) three times in 10 seconds. A short beep will be heard if the cancellation is successfully finished.

  1. Turn the ignition key to the “OFF” position.

  2. Set the plate (1) in the original position.

• Canceling of the system activation is possible regardless of whether or not the engine oil has been replaced. Once the system has operated, however, Suzuki strongly recommends that the engine oil be replaced before canceling the system activation.
• Even if the engine oil has been replaced with the system not operating, it is still necessary to perform the cancellation.

ENGINE STALLING CAUTION SYSTEM

This system informs the operator when the motor stalls while it is operating.

When the engine stalls for any reason, the caution buzzer sounds three times.

WATER IN FUEL ALERT SYSTEM

This engine is equipped with an integral fuel filter/water separator and associated alert system.

The alert system will activate if water separated from the fuel exceeds a specific volume.

If this system activates, the red REV-LIMIT lamp will flash and a buzzer will begin a series of double beeps when the engine is in neutral only.

If this system activates, stop the engine immediately, if wind and water conditions are safe to do so, and check the fuel filter/water separator for water. Or consult your authorized Suzuki marine dealer.

For inspection and cleaning of the fuel filter, refer to the LOW PRESSURE FUEL FILTER in the INSPECTION AND MAINTENANCE section.