Electrical System [Electrical Components Analysis] [2013]

Applicable Models

Model GroupYearModelSerial
Yamaha International2001 - 20058hpAll
Yamaha International2001 - 20056hpAll
Yamaha Outboard2001 - 20058hpAll
Yamaha Outboard2001 - 20056hpAll
Electrical System [Electrical Components Analysis] [2013]
Yamaha Marine

ELECTRICAL COMPONENTS ANALYSIS

DIGITAL CIRCUIT TESTER

Digital circuit tester: YU-34899-A/90890-06752

NOTE:
"o---------o" indicates a continuity of electricity which means a closed circuit at the respective switch position.

MEASURING THE PEAK VOLTAGE

WARNING:
When checking the peak voltage do not touch any of the connections of the digital tester lead wires.

NOTE:

  • When checking the condition of the ignition system it is useful to know the peak voltage.
  • Cranking speed is dependant on many factors (e.g., fouled or weak spark plugs, a weak battery). If one of three is defective, the peak voltage will be lower than specification.
  • If the peak voltage measurement is not within specification the engine will not operate properly.

PEAK VOLTAGE ADAPTOR

NOTE:
The peak voltage adaptor should be with the digital circuit tester.

Peak voltage adaptor: YU-39991/90890-03172

NOTE:

  • When measuring the peak voltage, set the selector to the DC voltage mode.
  • Make sure the peak voltage adapter lead are properly installed in the digital tester.
  • Make sure the positive pin (the "+" mark facing up as shown) on the peak voltage adapter is installed into the positive terminal of the digital tester.
  • The test harness is needed for the following tests.

Measuring steps:
(1) Connect the peak voltage adapter probes to the connectors.
(2) Start or crank the engine and observe the measurement.

MEASURING A LOW RESISTANCE

When measuring a resistance of 10 Ω or less with the digital tester, the correct measurement cannot be obtained because of the tester's internal resistance.

To obtain the correct value, subtract the internal resistance from the displayed measurement.

Correct value:
Displayed measurement - internal resistance

NOTE:
The internal resistance of the digital tester can be obtained by connecting both of its probes.