CHARGING SYSTEM

(1) Lighting coil
(2) Rectifier/regulator
(3) Fuse
(4) Battery
B : Black
R : Red
Y : Yellow
CHARGING SYSTEM PEAK VOLTAGE

- Measure:
• Rectifier/regulator output peak voltage
Excessively over specification -> Replace.
Excessively below specification -> Check the lighting coil.
Rectifier/regulator output (R - B)
| r/min | Cranking | Cranking | 1500 | 3500 |
|---|---|---|---|---|
| r/min | ✝ | * | 1500 | 3500 |
| V | 9 | 12.5 | 12.5 | 12.5 |
✝ : Open circuit
*: Loaded
- Measure:
• Lighting coil output peak voltage
Below specification -> Replace.
Lighting coil output peak voltage (Y-Y)
| r/min | Cranking | 1500 | 3500 |
|---|---|---|---|
| V | 8 | 26 | 60 |
FUSE
Refer to "STARTING SYSTEM".
BATTERY
Refer to "GENERAL" in chapter 3.